Search results for "Stereoscopic acuity"

showing 10 items of 10 documents

Stereopsis assessment at multiple distances with an iPad application

2017

[EN] We present a new application for iPad for screening stereopsis at multiple distances that allows testing up to ten levels of stereoacuity at each distance. Our approach is based on a random dot stereogram viewable with anaglyph spectacles. Sixty-five subjects with no ocular diseases, wearing their habitual correction were measured at 3 m and 0.5 m. Results were compared with a standard stereoscopic test (TNO). We found not statistically significant differences between both tests, but our method achieved higher reproducibility. Applications in visual screening programs and to design and use of 3D displays, are suggested. (C) 2017 Elsevier B.V. All rights reserved.

Computer science3D displaysStereoacuityIPad02 engineering and technologyStereo displayHuman-Computer InteractionStereoscopic acuity03 medical and health sciences0302 clinical medicineStereopsisDepth perceptionHardware and ArchitectureComputer graphics (images)FISICA APLICADA030221 ophthalmology & optometry0202 electrical engineering electronic engineering information engineering020201 artificial intelligence & image processingElectrical and Electronic EngineeringScreening stereopsisBinocular visionDepth perceptionBinocular vision
researchProduct

A Random Dot Stereoacuity Test based on 3D Technology

2014

This paper presents a novel stereo acuity test that is realized by a software program on a PC with 3D capabilities. The 3D technology is used to provide two separate images to the two eyes. The test is a classical random dot test, but differently to other test printed on paper, the images shown to the patient can vary and there is no monocular clue. These features allow to deliver the test also in groups (instead of individuals) like school classes, and to increase the sensitivity. The system can be easily used also by not specialized personnel and this may further increase the cost efficiency of the test. Experiments carried on with a large set of children of age between five and seven yea…

EngineeringMonocularrandomdot testCost efficiencybusiness.industryStereo acuitystereopsisTest (assessment)Stereoscopic acuitySoftwareamblyiopiaSettore ING-IND/15 - Disegno e Metodi dell'Ingegneria Industrialestereopsis randomdot test amblyiopia 3dComputer visionSensitivity (control systems)Artificial intelligencebusinessSimulation3dProceedings of the 8th International Conference on Pervasive Computing Technologies for Healthcare
researchProduct

Stereoacuity with balanced presbyopic contact lenses.

2010

Our aim was to evaluate near stereoacuity with the balanced Proclear Multifocal simultaneous vision contact lens. Twenty-five presbyopic subjects were fitted binocularly with the Proclear Multifocal contact lens and with distance contact lenses combined with reading spectacles, which served as controls. After one month, stereoacuity was measured using the vectographic Titmus and Random dot stereotests and the Howard-Dolman (HD) apparatus under photopic conditions (85 cd/m(2) ) at 40 cm. Binocular high-contrast visual acuities (BHCVA) at distance and near were examined. For the multifocal group, mean stereoacuity with the Howard-Dolman method was 22.40 ± 8.23 seconds of arc. Using the Titmus…

MaleVisual acuitygenetic structuresContact LensesVisual AcuityContrast SensitivitymedicineHumansVision testDepth PerceptionVision BinocularVision TestsPresbyopiaEquipment DesignPresbyopiaMiddle Agedmedicine.diseaseeye diseasesStereoscopic acuityOphthalmologyEyeglassesReadingOftalmologíaOptometryFemalemedicine.symptomDepth perceptionPsychologyBinocular visionOptometryClinicalexperimental optometry
researchProduct

Visual performance comparison between contact lens-based pinhole and simultaneous vision contact lenses.

2011

Background The aim was to evaluate the visual performance provided with a contact lens-based pinhole design against a simultaneous vision multifocal contact lens. Methods In a cross-over study at the University of Valencia, 22 presbyopic patients were evaluated using an artificial pupil fitted on the non-dominant eye and the simultaneous vision PureVision Multifocal contact lenses. After one month of contact lens wear, binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance contrast sensitivity, binocular near contrast sensitivity, and stereoacuity were measured, under photopic conditions (85 cd/m2). In addition, binocular distance vis…

MaleVisual acuitygenetic structuresMesopic visionContact Lensesmedia_common.quotation_subjectVisual AcuityContrast SensitivitymedicineContrast (vision)HumansMathematicsmedia_commonAgedVision BinocularCross-Over StudiesColor VisionEquipment DesignPresbyopiaMiddle Agedeye diseasesStereoscopic acuityContact lensOphthalmologyStereopsisTreatment OutcomeOptometryFemalemedicine.symptomBinocular visionOptometryPhotopic visionFollow-Up StudiesClinicalexperimental optometry
researchProduct

Artificial pupil versus contralateral balanced contact lens fit for presbyopia correction.

2014

Purpose: To assess and compare the effects of contact lens-based artificial pupil design and contralateral balanced multifocal contact lens combination (CBMCLC) on visual performance. Methods: This randomized crossover study conducted at the University of Valencia, Spain included 38 presbyopic patients using an artificial pupil contact lens in the nondominant eye and a CBMCLC. After a month of lens wear, the binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance, and near contrast sensitivity and near stereoacuity (NSA) were measured under photopic conditions (85 cd/m2). Moreover, BDVA and binocular distance contrast sensitivity were …

MaleVisual acuitygenetic structuresMesopic visionmedia_common.quotation_subjectLentes de contatoVisual AcuityPupilContrast Sensitivitylcsh:OphthalmologymedicineContrast (vision)HumansContact lensesPresbyopia/rehabilitationPupilaPresbiopia/reabilitaçãomedia_commonMathematicsCross-Over StudiesColor VisionPupilGeneral MedicinePresbyopiaEquipment DesignPresbyopiaMiddle Agedmedicine.diseaseContact Lenses HydrophilicAjuste de próteseeye diseasesContact lensStereoscopic acuityOphthalmologyTreatment Outcomelcsh:RE1-994Dominância ocularOptometryFemalemedicine.symptomProsthesis fitting dominance ocularPhotopic visionArquivos brasileiros de oftalmologia
researchProduct

Stereoacuity with simultaneous vision multifocal contact lenses.

2010

Our purpose was to evaluate near stereoacuity (SA) with Focus Progressives and PureVision Multifocal simultaneous vision contact lenses. In a cross-over study design, 20 presbyopic subjects were fitted with either the Focus Progressives or PureVision Multifocal lenses. After 1 month, SA was measured with the vectographic Titmus, Random dot stereotests, and the Howard-Dolman apparatus under photopic conditions (85 lux) at 40 cm. Binocular high-contrast visual acuity at distance and near was examined. Subjects were then refitted with the alternative correction and the procedure was repeated. Mean SA with the Focus Progressive was 21 +/- 7 sec arc, 54 +/- 17 sec arc, and 51 +/- 21 sec arc, wit…

Malebusiness.product_categoryVisual acuitygenetic structuresContact LensesLentes de contactoVisual AcuityMedicineHumansVision testMultifocal lensesDepth PerceptionCross-Over Studiesbusiness.industryVision TestsEquipment DesignPresbyopiaMiddle AgedStereoscopic acuityOphthalmologyOptometryOftalmologíaFemalemedicine.symptomDepth perceptionbusinessOptometryOptometry and vision science : official publication of the American Academy of Optometry
researchProduct

Visual Comparison of an Artificial Pupil Contact Lens to Monovision

2012

PURPOSE To assess and compare the effects of contact-lens based artificial pupil design and monovision correction on visual performance. METHODS In a cross-over study design, 22 presbyopic patients (age range 50 to 64 years) were evaluated using artificial pupil contact lens on the non-dominant eye and monovision. After 1 month, binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance contrast sensitivity, binocular near contrast sensitivity, and stereoacuity were measured, under photopic conditions (85 cd/m2), in each patient after contact lens fitting. Moreover, BDVA and binocular distance contrast sensitivity were examined under meso…

Malemedicine.medical_specialtyVisual acuitygenetic structuresContact LensesMesopic visionmedia_common.quotation_subjectVisual AcuityPupilVision MonocularOphthalmologymedicineHumansContrast (vision)media_commonMathematicsCross-Over StudiesPupilEquipment DesignPresbyopiaMiddle Agedeye diseasesContact lensStereoscopic acuityOphthalmologyTreatment OutcomeFemaleSpatial frequencymedicine.symptomFollow-Up StudiesOptometryPhotopic visionOptometry and Vision Science
researchProduct

Stereoacuity After Refractive Lens Exchange With AcrySof ReSTOR Intraocular Lens Implantation

2009

Purpose: To evaluate stereoacuity before and after refractive lens exchange (RLE) with AcrySof ReSTOR intraocular lens (IOL) implantation. Methods: Stereoacuity was measured using the Titmus stereotest at 40 cm under photopic conditions (85 cd/m 2 ) before and after RLE with bilateral AcrySof ReSTOR Natural (SN60D3 model) implantation in 30 hyperopic eyes of presbyopes with low astigmatism (⩽1.00 diopter [D]). Stereoacuity measurements after implantation were compared with those found before surgery. Results: Stereoacuity was unchanged after RLE with pseudoaccommodative IOL implantation. In this population of non-cataractous hyperopes with excellent preoperative stereoacuity (46.42±1.36 se…

Malemedicine.medical_specialtyVisual acuitygenetic structuresmedicine.medical_treatmentPopulationVisual AcuityIntraocular lensAstigmatismOpticsLens Implantation IntraocularOphthalmologymedicineHumanseducationDioptreLenses IntraocularDepth PerceptionVision Binoculareducation.field_of_studyPhacoemulsificationbusiness.industryPresbyopiaPresbyopiaPhacoemulsificationMiddle Agedmedicine.diseaseeye diseasesStereoscopic acuityOphthalmologyHyperopiaFemaleSurgerymedicine.symptombusinessJournal of Refractive Surgery
researchProduct

Multifocal intraocular lenses for unilateral cataract in children.

2009

Purpose To evaluate the implantation of apodized diffractive multifocal intraocular lenses (IOLs) in children with unilateral cataract. Setting Ophthalmology Service, Hospital Clinico Lozano Blesa, Zaragoza, Spain. Design Prospective clinical study. Methods Five children between 4 and 6 years of age with unilateral cataract had cataract extraction and implantation of an apodized diffractive multifocal IOL (AcrySof Restor SN60D3). Phacoaspiration was accompanied by posterior capsulorhexis followed by an anterior vitrectomy. Uncorrected distance (UDVA), corrected distance (CDVA), and corrected near (CNVA) visual acuities; binocular function using the Worth 4-dot test and the TNO stereotest; a…

Malemedicine.medical_specialtygenetic structuresPseudophakiamedicine.medical_treatmentEye diseaseVisual AcuityVitrectomyIntraocular lensCataractFunctional LateralityGlareLens Implantation IntraocularOphthalmologyVitrectomymedicineHumansProspective StudiesChildLenses IntraocularVision BinocularPhacoemulsificationbusiness.industryGlare (vision)PhacoemulsificationMultifocal intraocular lensmedicine.diseaseeye diseasesSensory SystemsStereoscopic acuityOphthalmologyAxial Length EyeChild PreschoolOptometrySurgeryFemalesense organsbusinessPseudophakiaFollow-Up StudiesJournal of cataract and refractive surgery
researchProduct

<title>Stereoacuity determination at changing contrast of colored stereostimuli</title>

2003

Studies are focused on design and appraisal of an objective test for assessment of the stereovision quality in unfavorable conditions. Stereostimuli of different colors are used while the contrast of one of the stimulus being varied. Tests are based on principles of black-and-white and two primary color random dot stereotests. Experiments are divided by the method of stimuli display and separation: 1) stereoeffect is obtained haploscopically - by use of spectacles with color filters (blue and red) or prisms, 2) stimuli separation is obtained by liquid crystal shutters when both eye stimuli are demonstrated with a different delay. The stereovision threshold is determiend at different stimuli…

business.product_categoryComputer sciencebusiness.industryContrast (statistics)Stimulus (physiology)Stereoscopic acuityPrimary colorColoredRGB color modelComputer visionColor filter arrayArtificial intelligenceComputer monitorbusinessSPIE Proceedings
researchProduct